up to 4kW 1Ph-230V, K3000 series - KLINGER BORN

Skip Navigation

Choose language

Sie befinden sich hier: Products » Starters » Switch-Plug-Combinations » up to 4kW 1Ph-230V, K3000 series » Example combinations

Caption

  • versions
  • dimension sheet
  • example combinations
  • options
  • send request

Example combinations K3000 - up to 4.0 kW 1 phase 230 V


Please note that all our switches are custom-made. Because of the numerous ways the individual components can be combined, we can offer a high number of different models. For the same reason, there are no switches available on stock. The following combinations merely illustrate the wide range of possibilities, they are not available on stock. Delivery time on enquiry.


K3000 / GB / ST6 / KA3 / Therm
Model-No.: 0098.3700

K3000, Mod.No. 0098.3700
Circuit diagram 0098.3700

Technical data:

Undervoltage trigger
Uc: 230 V/50 Hz
Switching capacity
4.0 kW 230 V~/AC-3
Ie
16.0 A
Plug
Earthing-pin plug 2P+E 16A according to CEE7/VII
Electronic brake
Up to 20A type VB, see option electronic brake
Connecting lead
1 mtr. S07RN-F 7G 1.5 with facility for connecting a thermistor contact
Protection type
IP54
Fixing dimensions
68 x 68 mm
Case color
Grey
Grip
Red, lockable
Plug color
Blue

K3000 / GB / ST6 / KA3 / Therm/ Not
Model-No.: 0098.3710

K3000, Mod.No. 0098.3710
Circuit diagram 0098.3710

Technical data:

Undervoltage trigger
Uc: 230 V/50 Hz
Switching capacity
4.0 kW 230 V~/AC-3
Ie
16.0 A
Plug
Earthing-pin plug 2P+E 16A according to CEE7/VII
Electronic brake
Up to 20A type VB, see option electronic brake
Emergency-stop
Integrated in case, see option emergency-stop
Connecting lead
1 mtr. S07RN-F 7G 1.5 with facility for connecting a thermistor contact
Protection type
IP54
Fixing dimensions
68 x 68 mm
Case color
Grey
Grip
Red, lockable
Plug color
Blue

K3000 / GB / NKA6 / KA12 / End / Mx,xA
Model-No.: 0098.3720

K3000, Mod.No. 0098.3720
Circuit diagram 0098.3720

Technical data:

Undervoltage trigger
Uc: 230 V/50 Hz
Switching capacity
4.0 kW 230 V~/AC-3
Ie
16.0 A
Electronic brake
Up to 20A type VB, see option electronic brake
Overload protection
Type KB-SM-30, see option overload protection
Mains lead
2 mtr. H07RN-F 3G 1.5 with injected earthing-pin plug 2P+E 16A according to CEE7/VII
Connecting lead
1 mtr. H07RN-F 3G 1.5
Additional lead
1 mtr. H05RN-F 2x 1.0 (for liwith switch or emergency-stop)
Protection type
IP54
Fixing dimensions
68 x 68 mm
Case color
Grey
Grip
Red

Please specify rated motor current !!!
Model-No.: 0098.3720 M....,..A


K3000 / ST6 / KA3 / L-0-R / Mx,xA
Model-No.: 0098.3730

K3000, Mod.No. 0098.3730
Circuit diagram 0098.3730

Technical data:

Undervoltage trigger
Uc: 230 V/50 Hz
Switching capacity
4.0 kW 230 V~/AC-3
Ie
16.0 A
Cam-Switch
Switch for right-left running, see option direction reversal
Overload protection
Type KB-SM-30, see option overload protection
Plug
Earthing-pin plug 2P+E 16A according to CEE7/VII
Connecting lead
1 mtr. H07RN-F 5G 1.5
Protection type
IP54
Fixing dimensions
68 x 68 mm
Case color
Grey
Grip
Red
Plug color
Blue

Please specify rated motor current !!!
Model-No.: 0098.3730 M....,..A


Terminal leads are stripped to a length of 100mm and fitted with connector sleeves.
Prices on request.

Search website