Control PCB Automatic starter - KLINGER BORN

Skip Navigation

Choose language

Sie befinden sich hier: Products » Control devices and Timer » Control PCB Automatic starter

Control PCB for Automatic Switching Unit

- Delayed starting of your second drive for best mains fuse protection

- Supports delayed switching off

Control PCB

Special featues:

  • Effective protection of your back-up fuse
  • No second control panel for second drive required
  • Automatic starting of your second drive (e.g. dust extractor)
  • Automatic delayed switching off your second drive

Technical data:

Article number
870 058 02 = 230V
870 059 02 = 400V
Input voltage
230 V/50-60 Hz
400 V/50 Hz
Permissible voltage range
85-110 %
Current input
7 A and 16 A
Making threshold
Adjustable by potentiometer
Range 7 A = approx. 0.4 A
Range 16 A = approx. 1.0 A
Switching times
Adjustable by potentiometer
Making delay
Approx. 1.8 sec. - 4.5 sec.
Breaking delay
Approx. 5 sec. - 15 sec. (depends on making relay)
Ambient temperature
0 ... +45 °C
Output signal
Potential-free contact
Dimensions of control PCB
75 x 54 x 28 mm (LxWxH)
Switching relay
Potential-free contact for control circuit actuation
Nominal voltage
250 V AC
Making current
5 A
Nominal switching capacity
1250 VA
Test voltage open contact
750 V AC eff

Use in series:

Circuit diagram [pdf-File]


Functional description:

Closing delay devices are used for delayed switching on of motors and other inductive loads. This is important for trouble-free start-up. Starting a motor creates high starting currents that exceeds the nominal current approximately by a factor of 6. Starting two motors simultaneously can create starting currents that trigger the back-up fuse. To prevent this from happening, closing delay units are used to start the second drive after a certain time delay. This provides an additional advantage: The second drive will start automatically and without operator intervention after approximately 1 - 4 seconds. After switching off the main drive, the second drive will be switched off with a certain delay. This feature is useful for dust extractors and many other applications.