Features
- Input voltage: 400 V/50 Hz
- Total load (max.): 16 A or 7.5 kW
- Mains connection: Three-phase 400 V 16 A
- Switch-on threshold: min. 1.2 A (The current in the master circuit must be min. 1.2 A!)
- Each master socket independently activates the two slave sockets
Please note
To ensure functionality, the extraction system must not have an undervoltage release.
Models and Prices Automatic starting three-phase
Image | Master | Slave | Dimensions L x W x H in mm | Weight in kg (ca.) | Art.-No. | Price incl. VAT |
---|---|---|---|---|---|---|
1x CEE socket outlet 3 P+N+E 400 V/16 A 1x Schuko socket outlet 2 P+E 230 V | 1x CEE socket outlet 3 P+N+E 400 V/16 A 1x Schuko socket outlet 2 P+E 230 V | 230 x 106 x 145 | 1.18 | 0098.3915 | € 102,64 Order In Stock: 315 | |
1x CEE socket outlet 3 P+N+E 400 V/16 A 1x Schuko socket outlet 2 P+E 230 V with manual-0-auto selector switch for suction | 1x CEE socket outlet 3 P+N+E 400 V/16 A 1x Schuko socket outlet 2 P+E 230 V | 257 x 125 x 146 | 1.29 | 0098.3928 | € 113,92 Order In Stock: 88 |
Functional description
Automatic starting units are used for delayed switching of motors and other inductive loads. This is important to ensure a failure-free start-up. Starting a motor creates high starting currents that exceed the rated current approximately by a factor of 6. Starting two or more motors simultaneously can create starting currents that trigger the fuse. To prevent this from happening, automatic starting units are used to start the second drive after a certain time delay. This provides an additional advantage: The second drive will start automatically and without operator intervention after approximately 3 seconds. After switching off the main drive, the second drive will be switched off with a certain delay. This feature is useful for dust extractors and many other applications. The suction switch (slave) can also be put into operation via the auto-0-hand switch (optional) even if the saw (master) is not switched on.
Technical data
Art.-No. | 0098.3915 0098.3928 with manual mode for manual operation of the suction |
Input voltage | 400 V/50 Hz |
Mains connection | 3 Ph-400 V 16 A CEE 3 P+N+E 400 V with phase inverter |
Max. total load | 16 A or 7.5 kW |
Master/Slave Art.-No.: 0098.3915 0098.3928 | Master: 1x CEE socket outlet 3 P+N+E 400 V 1x Schuko socket outlet 2 P+E 230 V |
Slave: 1x CEE socket outlet 3 P+N+E 400 V 1x Schuko socket outlet 2 P+E 230 V | |
Allowable load current (Master) | 16 A |
Max. output load (switched) | 0098.3915 and 0098.3928: 4.0 kW 400 V/AC-3 |
Please note | The total load of master and slave must not exceed the maximum output load |
Power contactor for slave | 0098.3915 and 0098.3928: Undervoltage release KB04 |
Data circuit board | Circuit boards |
Switching on threshold | Min.1.2 A (The current in the master circuit must be min.1.2 A!) |
Breaking threshold | Approx. 300 mA |
Making delay | Approx. 3 s |
Breaking delay | Approx. 8 s |
Dimensions of control PCB | 75 x 55 x 31 mm (LxWxH) |