Automatic star-delta starter 7.5kW 400V/AC-3 32A
with undervoltage release, overload protection, L-0-R switching, emergency stop, cam switch KB-N25
Item No. 0099.0173
Setting for the built-in overload protection:
(setting values for overload protection = rated motor current x 0.58)
Rated motor current 6.0-8.3 = setting 3.5-4.8A
Rated motor current 7.8-10.9 = setting 4.5-6.3A
Rated motor current 9.5-12.0 = setting 5.5-7.5A
Rated motor current 12.4-17.2 = setting 7.2-10.0A (*)
(*) Fitted as standard
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0099.0173 | On request | 0 |
Technical Features
Series Specifications
Star-delta conversion
Automatic
Network form
3-phase 400V
Housing color
gray
Individual Parameters
Switching power
7.5kW 400V~/AC-3
Under-voltage release
400V/50Hz
Yes
32 A
Star-delta conversion
Automatically with adjustable ramp-up time via KLIBO star-delta timer.
Max. rated motor current
19 A
Overload protection
Yes, adjustable
Setting overload protection
Motor rated current x 0.58t - Please provide motor rated current at the end of the ordering process.
Note on motor
The motor must be suitable for a 400V delta connection.
electronic brake
No
Main switch
No
Emergency stop
No
L-0-R switching
Yes
Network connection
CEE neck plug 3P+N+E 400V 32A
Motor connection
2m PUR 7G2.5mm²
Limit switch connection possible
No
Enclosure
K4000
Housing dimensions (LxWxH)
240 x 190 x 128 mm
Mounting dimension
5.3mm through holes 152x223mm and M5 threaded inserts 94x200mm
protection type
IP54
Manufacturer