Features
- Input voltage: 230 V/50 Hz
- Total load: 16 A or 3.6 kW
- Max. output load: 3.0 kW 230 V/AC-3
- Switch-on threshold: min. 1.2 A (The current in the master circuit must be min. 1.2 A!)
Please note
To ensure functionality, the extraction system must not have an undervoltage release.
Models and Prices Automatic starting single-phase, 230 V
Image | Description | Dimensions L x W x H in mm | Weight in kg (ca.) | Art.-No. | Price incl. VAT |
---|---|---|---|---|---|
With shrouded plug | 231 x 106 x 108 | 0.74 | 0098.3902 | € 79,22 Order In Stock: 15 | |
With shrouded plug and manual-0-auto selector switch for suction | 258 x 106 x 108 | 0.84 | 0098.3926 | € 100,32 Order In Stock: 103 | |
With mains lead
| 180 x 106 x 108 | 1.2 | 0098.3908
| € 92,36 Order In Stock: 57
| |
With mains lead and manual-0-auto selector switch for suction
| 207 x 106 x 108 | 1.28 | 0098.3927
| € 116,83 Order In Stock: 47
|
Functional description
Automatic starting units are used for delayed switching of motors and other inductive loads. This is important to ensure a failure-free start-up. Starting a motor creates high starting currents that exceed the rated current approximately by a factor of 6. Starting two or more motors simultaneously can create starting currents that trigger the fuse. To prevent this from happening, automatic starting units are used to start the second drive after a certain time delay. This provides an additional advantage: The second drive will start automatically and without operator intervention after approximately 3 seconds. After switching off the main drive, the second drive will be switched off with a certain delay. This feature is useful for dust extractors and many other applications.
Technical data
Input voltage | 230 V/50 Hz |
Mains connection | Art.-No. 0098.3902: Shrouded plug 1 Ph-230 V 16 A Schuko |
Max. total load | 16 A or 3.6 kW |
Master outlet | 1x Schuko socket outlet 2 P+E 230 V |
Allowable load current | 16 A |
Slave outlet | 1x Schuko socket outlet 2 P+E 230 V |
Max. output load (switched) | 3.0 kW 230 V/AC-3 |
Please note | The total load of master and slave must not exceed the maximum output load |
Power contactor for slave | KB-04 See option undervoltage release |
Data circuit boards | Circuit boards |
Switching on threshold | Min.1.2 A The current in the master circuit must be min.1.2 A!) |
Breaking threshold | Approx. 300 mA |
Making delay | Approx. 3 s |
Breaking delay | Approx. 8 s |
Dimensions of control PCB | 75 x 55 x 31 mm (LxWxH) |