- Undervoltage trip
- Overload protection, with overload relay or thermistor relay
- Emergency stop switch
- electric brake
- automatic start Y-Δ
- additional connection option for feed
- Connections with spring terminals
- for external control panel
With undervoltage release, Dahlander switch Δ/YY, overload protection, emergency stop
Pos. 1 Art.-No.: 0098.4085 | Starter 3Ph-400V with Dahlander changeover Δ / YY With undervoltage release, overload protection, emergency stop. Control voltage 230V. Protection against automatic restart after voltage return | Price incl. VAT |
---|---|---|
| € 253,04 Get a quote In Stock: 0
€ 21,99 Order In Stock: 99 |
With undervoltage release, Dahlander switch Δ/YY, electronic brake, overload protection, emergency stop
Pos. 1 Art.-No.: 0098.4086 | Starter 3Ph-400 V up to 5.5 kW (optional up to 7.5 kW) With undervoltage release, overload protection, main switch, Dahlander switch Δ/YY, electronic brake, emergency stop. Control voltage 400V. Protection against automatic restart after voltage return | Price incl. VAT |
---|---|---|
| € 314,86 Order In Stock: 5
€ 21,99 Order In Stock: 99 |
With undervoltage release, overload protection, app. L-R + I-0-II, emergency stop, Dahlander Y-Δ-YY with autom. star-delta start
Pos. 1 Art.-No.: 0099.0434 | Control for Dahlander motor Y-Δ-YY, up to 7.5kW with 2x3-pin overload release for both stages with undervoltage release, with electronic brake, autom. Start Y-Δ, for ext. Operation, I-0-II and left-right, control transformer, main switch, additional connection for motor (feed or height adjustment) | Price incl. VAT | |
---|---|---|---|
Housing | Metal body 500x500x250 mm, grey | € 1.437,79 Get a quote In Stock: 0
€ 28,93 Order In Stock: 99
| |
Power connection | 3P+N+E 400 V 16 A Terminal blocks for mains connection/400 V | ||
Maximum engine power | 7,5 kW / 400 V (Adjust overload protection!) Other performance classes on request | ||
Control voltage | Uc: 230V/50 Hz with isolating transformer 315 VA, control fuse 2 A | ||
Main switch | 40 A/400 V AC-23 20 kW | ||
Controls | External, connection via spring terminals | ||
Brake | Electric brake Klibo-Phase-Brake 400 V, Braking current 16 A | ||
Overload protection | 2x3-pole overload relay,adjustable Level I = 10-13 A Level II = 13-16 A Other setting ranges possible TF42 Overloadrelay If required, please order via the price button (on the right). | ||
Connection for auxiliary drive | With motor protection switch 4.0 - 6.3 A If required, please order via the price button (on the right). | ||
230V connection, e.g. for displays | 230V max. 0.5A with 500mA fuse, connection via spring-loaded terminals | ||
Connection | Spring terminals for mains, motor; Auxiliary motor 230V/0.5A connection and external control panel | ||
Technical drawings | Wiring diagram | ||
Dimensional drawing | |||
Other versions on request | |||
External control panel option | Case 180x80x70 mm with L-R selector switch, I-0-II | € 81,99 Order In Stock: 1
€ 40,84 Get a quote In Stock: 0 | |
Control line option | 3 m 14G1.5 for connection of external control panel 8505.7303 | ||
Emergency stop option | Emergency stop box 8506.3412 | € 20,83 Order In Stock: 58 |
Pos. 2 Art.-No.: 0099.0435 | Control for Dahlander motor Y-Δ-YY, up to 7.5kW with thermistor relay with undervoltage release, with electronic brake, autom. Start Y-Δ, for ext. Operation, I-0-II and left-right, control transformer, main switch, additional connection for motor (feed or height adjustment) | Price incl. VAT | |
---|---|---|---|
Housing | Metal body 500x500x250 mm, grey IP66 | € 1.429,79 Get a quote In Stock: 0
€ 21,99 Order In Stock: 99 | |
Power connection | 3P+N+E 400 V 16 A Terminal blocks for mains connection/400 V | ||
Maximum engine power | 7,5 kW / 400 V (Adjust overload protection!) Other performance classes on request | ||
Control voltage | Uc: 230V/50 Hz with isolating transformer 315 VA, control fuse 2 A | ||
Main switch | 40 A/400 V AC-23 20 kW | ||
Controls | External, connection via spring terminals | ||
Brake | Electric brake Klibo-Phase-Brake 400 V, Braking current 16 A | ||
Overload protection | with thermistor relay ABB CM-MS.13 S | ||
Connection for auxiliary drive | With motor protection switch 4.0 - 6.3 A If required, please order via the price button (on the right). | ||
230V connection, e.g. for displays | 230 V max. 0.5 A with 500 mA fuse, connection via spring-loaded terminals | ||
Connection | Spring terminals for mains, motor; Auxiliary motor 230V/0.5A connection and external control panel | ||
Technical drawings | Wiring diagram | ||
Dimensional drawing | |||
Other versions on request | |||
External control panel option | 8505.7303 - Case 180x80x70 mm with L-R selector switch, I-0-II | € 81,99 Order In Stock: 1
€ 40,84 Get a quote In Stock: 0 | |
Control line option | 3 m 14G1.5 for connection of external control panel 8505.7303 | ||
Emergency stop option | Emergency stop box 8506.3412 | € 20,83 Order In Stock: 58 |