Features
- Input voltage: 400 V/50 Hz
- Total load (max.): 16 A or 7.5 kW
- Mains connection: Three-phase 400 V 16 A
- Switch-on threshold: min. 1.2 A (The current in the master circuit must be min. 1.2 A!)
Please note
To ensure functionality, the extraction system must not have an undervoltage release.
Versions and prices automatic switch-on 3Ph
Image | Shrouded plug | Master | Slave | Dimensions L x W x H in mm | Weight ca. in kg | Art.-No. | Price incl. VAT |
---|---|---|---|---|---|---|---|
16 A | 3x CEE socket outlet 3 P+N+E 400 V/16 A 1x Schuko socket outlet 2 P+E 230 V | 1x CEE socket outlet 3 P+N+E 400 V/16 A
| 301 x 244 x 182 | 2.47 | 0098.3909
| € 198,54 Order In Stock: 10
| |
16 A | 3x CEE socket outlet 3 P+N+E 400 V/16 A
with selector switch hand-0-auto for suction
| 1x CEE socket outlet 3 P+N+E 400 V/16 A
| 301 x 244 x 182 | 2.58 | 0098.3929
| € 211,87 Order In Stock: 33
|
Functional description
Automatic starting units are used for delayed switching of motors and other inductive loads. This is important to ensure a failure-free start-up. Starting a motor creates high starting currents that exceed the rated current approximately by a factor of 6. Starting two or more motors simultaneously can create starting currents that trigger the fuse. To prevent this from happening, automatic starting units are used to start the second drive after a certain time delay. This provides an additional advantage: The second drive will start automatically and without operator intervention after approximately 3 seconds. After switching off the main drive, the second drive will be switched off with a certain delay. This feature is useful for dust extractors and many other applications. The suction switch (slave) can also be put into operation via the auto-0-hand switch (optional) even if the saw (master) is not switched on.
Technical data
Art.-No. | 0098.3909 16 A, combi 0098.3929 16 A, combi with manual mode for manual operation of the suction |
Input voltage | 400 V/50 Hz |
Mains connection | 3 Ph-400 V 16 A CEE 3 P+N+E 400 V mit phase inverter |
Total load (max.) | 16A or 7,5 kW |
Master/Slave | Master: 1x CEE socket outlet 3 P+N+E 400 V 1x Schuko socket outlet 2 P+E 230 V |
Slave: 1x CEE socket outlet 3 P+N+E 400 V 1x Schuko socket outlet 2 P+E 230 V | |
Permissible load current (master) | 16 A |
Max. Output load (switched) | 7,5 kW 400 V/AC-3 |
Please note | The total load of master and slave must not exceed the maximum output load |
Contactor for slave | Undervoltage release Klibo7,5 |
Data control board | Circuit boards |
Switch-on threshold 0098.3909, 0098.3929 | Min.1.2 A (The current in the master circuit must be min.1.2 A!) |
Switch-off threshold 0098.3909, 0098.3929 | Approx. 300 mA |
Switch-on delay 0098.3909, 0098.3929 | Approx. 3 sec. |
Switch-off delay 0098.3909, 0098.3929 | Approx. 8 sec. |