Automatic switch-on 3 Ph, 400 V with fastening straps and adjustable with adjustable switching times and switching threshold
Features
- Input voltage 400 V / 50 Hz
- Total load (max.) 16 A or 7.5 kW
- Mains connection 3 Ph-400 V 16 A
- With fastening straps
- With adjustable switching time and switching threshold (CCST-board)
Please note:
In order to ensure functionality, the extraction system must not have an undervoltage release.
Models and Prices 3Ph automatic switch-on 3Ph-400 V, with adjustable switching times and switching threshold
Image | Master | Slave | Art.-No. | Price incl. VAT |
---|---|---|---|---|
1x CEE socket 3 P + N + E 400 V / 16 A 1x Schuko socket 2 P + E 230 V With CCST-board | 1x CEE socket 3 P + N + E 400 V / 16 A 1x Schuko socket 2 P + E 230 V | 0098.3932 | € 132,64 Order In Stock: 75 | |
1x CEE socket 3 P + N + E 400 V / 16 A 1x Schuko socket 2 P + E 230 V with manual-0-auto selector switch for suction With CCST-board | 1x CEE socket 3 P + N + E 400 V / 16 A 1x Schuko socket 2 P + E 230 V | 0098.3933 | € 153,75 Order In Stock: 65 |
Function description
Switch-on delays are used to e.g. Switching electric motors or other inductive loads on and off with a time delay. This is an important facility to ensure trouble-free start-up. When electric motors are switched on, high inrush currents occur, which can amount to approx. 6 times the value of the rated current. If you now switch on two motors at the same time, the starting currents are in a range where the upstream fuse can trip. To prevent this, the second drive is switched on with the help of a switch-on delay. This has the further advantage that the second drive switches on automatically after approx. 3 seconds without further operation and switches off again automatically after the main drive has been switched off. This is a useful facility for suction equipment and much more. Using the auto-0-hand switch (optional), the suction (slave) can also be started when the saw (master) is not switched on.
Technical data
Art.-No. | 0098.3932 with CCST control board and fastening straps 0098.3933 like 0098.3932 but with additional manual-0-automatic |
Input voltage | 400 V/50 Hz |
Netzanschluss | 3 Ph-400 V 16 A CEE 3 P+N+E 400 V with phase inverter |
Total load (max.) | 16 A or 7.5 kW |
Master/Slave Mod.No.: 0098.3932 0098.3933 | Master: 3x CEE socket 3 P+N+E 400 V 1x Schuko socket 2 P+E 230 V |
Slave: 1x CEE socket 3 P+N+E 400 V 1x Schuko socket 2 P+E 230 V | |
Permissible load current (master) | 16 A |
Max. Output load (switched) | 0098.3932 and 0098.3933: 5.5 kW 400 V/AC-3 |
Please note | The permissible total connected load of master and slave must not exceed the specified total load. |
Contactor for slave | 0098.3932: Undervoltage release ISKRA K07 0098.3933: Undervoltage release ISKRA K07 |
Data control board | Control board |
Switch-on threshold | Version with CCST board ~ 0.1 ... 0.6 A adjustable |
Switch-off threshold | ~0.1 ... 0.4 A |
Switch-on delay | ~0.5 ... 8 s adjustable |
Switch-off delay | ~0.1 ... 12 s adjustable |
Dimensions of the control board | 75 x 55 x 31 mm (LxWxH) |