Automatic starting 1 Ph and 3 Ph, connections via spring-loaded terminals, adjustable switch-on switch-off time and switching threshold, with emergency-stop switch
Features
- With emergency-stop switch
- Input voltage 1 Ph-230 V or 3 Ph-400 V
- Total load max. 11,5 W / 400 V
- Mains connection 1 Ph-230 V or 3 Ph-400 V 16 A (with neutral)
- Connections via spring-loaded terminals
- With adjustable on / off time and switching threshold
Please note:
In order to ensure functionality, the extraction system must not have an undervoltage release.
Models and Prices automatic starting 1 Ph and 3 Ph (adjustable with CCST control board)
Image | Master | Slave | Art.-No. | Price incl. VAT |
---|---|---|---|---|
2x 3 P+N+E 2x P+N+E Connections via spring-loaded terminals | 1x 3 P+N+E or 1x P+N+E Connections via spring-loaded terminals | 0098.3939 | € 206,22 Order In Stock: 14 |
Function description
Switch-on delays are used to e.g. Switching electric motors or other inductive loads on and off with a time delay. This is an important facility to ensure trouble-free start-up. When electric motors are switched on, high inrush currents occur, which can amount to approx. 6 times the value of the rated current. If you now switch on two motors at the same time, the starting currents are in a range where the upstream fuse can trip. To prevent this, the second drive is switched on with the help of a switch-on delay. This has the further advantage that the second drive switches on automatically after approx. 3 seconds without further operation and switches off again automatically after the main drive has been switched off. This is a useful facility for suction equipment and much more. Using the auto-0-hand switch (optional), the suction (slave) can also be started when the saw (master) is not switched on.
Technical data
Art.-No. | 0098.3939 |
Operating voltage | 1 Ph-230 V or 3 Ph-400 V |
Mains connection | 1 Ph-230 V or 3 Ph-400 V (with neutral) |
With emergency-stop switch | 32 A, 11.5 kW AC-23 |
Max. total load | 11.5 kW / 400 V |
Master/Slave Mod.No.: 0098.3939 | Master: 2x 3 P+N+E 2x P+N+E |
Slave: 1x 3 P+N+E or P+N+E | |
Permissible load current (master) | 16 A |
Max. switched output load (slave) | 7.5 kW / 400 V or 4.0 kW / 230 V |
Please note | The permissible total connected load of master and slave must not exceed the specified total load. |
Contactor for slave | Klibo 7,5 |
Line inputs | 3x M 20 cable gland, 3x M 20 blind plug |
Mains, motor and slave connections | WAGO TOPJOB spring-loaded clamps, 2.5m² Clamping area solid conductor 0.25...4mm² Clamping area fine-stranded 0.25..4mm² Stripping length 10...12mm |
Data control board | Control boards |
Switch-on threshold | Version with CCST board ~ 0.1 ... 0.6 A adjustable |
Switch-off threshold | ~0.1 ... 0.4 A |
Switch-on delay | ~0.5 ... 8 s adjustable |
Switch-off delay | ~0.1 ... 12 s adjustable |
Dimensions of the control board | 75 x 55 x 31 mm (LxWxH) |
Pre-fuse | 16A gL/gG |
Max. switching frequency | 120/h |
Ambient temperature | -10°C ... +40°C |
Protection type | IP56 |
Housing | Technopolymer, grey. IK07 |
Weight | 3,0 kg |