Features
- Input voltage: 230 V / 50 Hz
- Total load: 16 A or 3.6 kW
- Mains connection 1 Ph-230 V 16 A
- Max. Output load: 3.0 kW 230 V / AC-3
- Optional with fastening straps
- With adjustable switching times and switching threshold (CCST-board)
Please note
In order to ensure functionality, the extraction system must not have an undervoltage release.
Models and Prices automatic starting 1 Ph-230, adjustable switching times an switching threshold
Image | Description | Dimensions L x W x H in mm | Weight in kg (ca.) | Art-No. | Price incl. VAT |
---|---|---|---|---|---|
With shrouded plug With CCST-board | 246 x 106 x 114 | 0.8 | 0098.3936 | € 99,60 Order In Stock: 18 | |
With shrouded plug and manual-0-auto selector switch for suction With CCST-board | 258 x 106 x 114 | 0.9 | 0098.3937 | € 126,93 Order In Stock: 19 | |
With mains lead
| 180 x 106 x 108 | 1.24 | 0098.3948
| € 103,66 Order In Stock: 4
| |
With mains lead and manual-0-auto selector switch for suction
| 207 x 106 x 108 | 1.32 | 0098.3947
| € 128,14 Order In Stock: 2
|
Functional description
Automatic starting units are used for delayed switching of motors and other inductive loads. This is important to ensure a failure-free start-up. Starting a motor creates high starting currents that exceed the rated current approximately by a factor of 6. Starting two or more motors simultaneously can create starting currents that trigger the fuse. To prevent this from happening, automatic starting units are used to start the second drive after a certain time delay. This provides an additional advantage: The second drive will start automatically and without operator intervention after approximately 3 seconds. After switching off the main drive, the second drive will be switched off with a certain delay. This feature is useful for dust extractors and many other applications.
Technical data
Input voltage | 230 V/50 Hz |
Mains connection | Art.-No. 0098.3936: With shrouded plug, with CCST control board and fastening straps |
Total load (max.) | 16 A or 3.6 kW |
Master (working socket) | 1x Schuko socket 2 P+E 230 V |
Permissible load current | 16 A |
Slave (switched socket) | 1x Schuko socket 2 P+E 230 V |
Max. Output load (switched) | 3.0 kW 230 V/AC-3 |
Please note | The permissible total connected load of master and slave must not exceed the specified total load. |
Contactor for slave | 0098.3936: Underroltage release ISKRA K07 0098.3937: Undervoltage release ISKRA K07 0098.3948: Undervoltage release KLIBO KB-04 0098.3947: Undervoltage release KLIBO KB-04 |
Data control board | Control boards |
Switch-on threshold | Version with CCST board ~ 0.1 ... 0.6 A adjustable |
Switch-off threshold | ~0.1 ... 0.4 A |
Switch-on delay | ~0.5 ... 8 s adjustable |
Switch-off delay | ~0.1 ... 12 s adjustable |
Dimensions of the control board | 75 x 55 x 31 mm (LxWxH) |