Automatic shutdown

PCB Automatic switch-off
Description

Features

  • Safe shutdown of the main contactor despite the generator action of the motor
Series Specifications

Permissible voltage range

85-110 %

current input

16A continuous, 35A for 5s

Switched output contact

3A continuous, 5A inrush current

Note

For switching a control circuit; standard version: contact dependent on potential; special version: contact isolated from potential.

Test voltage open contact

750 V AC eff

Switch-on threshold

~ 0.6A; Adjustable version ~ 0.1....0.6A

cut-off threshold

~ 0.4A; Adjustable version ~ 0.1....0.4A

Turn-on delay

~ 3s; Adjustable version ~ 0.5....8s

turn-off delay

~ 7s; Adjustable version ~ 0.1....12s

Current consumption, power

22mA / 0.6W

Ambient temperature

0 ... +45°C

Dimensions 230V version (LxWxH)

75 x 54 x 18.5 mm

Dimensions 400V version (LxWxH)

75 x 54 x 21.5 mm

Description CCST, current-controlled shutdown automation

CCST current-controlled shut-off system without delay

We have developed a new control board CCST (Current Control Switch Timer), which detects the shut-off and ensures that the main contactor safely disconnects despite the generator effect of the motor. This control board ensures that in the case of a brief power interruption (greater than 0.2s), no restart occurs and when the power coupling is disconnected, the pins of the SSK or the power line are voltage-free within a maximum of 0.6s. Thus, we safely meet the requirement according to DIN EN 60204 with a maximum of 60V after 1s.

The current-controlled shut-off system opens a relay in self-holding mode during a power supply interruption. If the power supply is resumed afterwards, uncontrolled restarting of a machine is safely prevented. Unlike a voltage monitoring relay, this works even when a rotating machine with inertia still induces a voltage.

The shut-off system receives its operating voltage via terminals L1 and N.

The control signal of the after-run control is the load current of the connected consumer. The controlling consumer is connected between terminals L1 Load and N.

When the consumer is switched on, the relay pulls in without delay and connects contact SP with terminal N. As soon as the load current is interrupted, the relay is opened again without delay. The relay thus controls the self-holding circuit.

Depending on the version, the module may only be operated at 230V or 400V.

There must be a protection device for this module.

When applying the operating voltage to the shut-off system, the relay closes briefly. This implies that an electromechanical contact of the contactor must be in series with the SP contact. The operating voltage must also be present at the shut-off system before the consumer is switched on.

If a potential-free switching contact is required, the bridge (through-hole) between terminals N and NSP must be separated using a 3mm drill. The copper ring around the hole should be completely removed. The switching contact of the relay is then between SP and NSP.

Versions
 Auf Lager : 237
CCST shutdown automation 230V/16A
current-controlled, without delay
Item No.: 8700.5920

Price 46,16 €
inkl. VAT­ + Shipping

CCST shutdown automation 400V/16A
current-controlled, without delay
Item No.: 8700.5921

Price 49,47 €
inkl. VAT­ + Shipping

 Auf Lager : 1
CCST shutdown automation 230V/16A
current-controlled, without delay
Item No.: 8700.5922

Price 47,40 €
inkl. VAT­ + Shipping

CCST shutdown automation 400V/16A
current-controlled, without delay
Item No.: 8700.5923

Price 50,69 €
inkl. VAT­ + Shipping