Starter 3Ph-400V, Series K400/3Ph
with undervoltage release according to IEC 204-1, 1992, EN 60204, VDE 0113, section 7.5

Description
Features
- With undervoltage release (standard) for protection against unintentional restarting after voltage drop and voltage recovery
- Ideal switch for pillar drilling machines, grinding machines, and much more.
Please note that the following versions are example configurations. Due to the many combination possibilities of the individual components, we are able to produce a variety of models. If your desired configuration is not included in these versions, please contact us.
Note on plug direction and cable outlet:
Plug direction and cable outlet refer to the control panel. The control panel always points to 6 o'clock, see illustration under "Further views and drawings".
Series Specifications
Start-up
Direct start
Rated operating voltage Ue
400V/50Hz
rated switching capacity
4.0kW 400V~
Rated operational current Ie
9.0 A
Connection
3-phase 400V
contactor
KB-04
Network input
CEE plug or power cable
Type of actuation
Push buttons On/Off
Keypad
with protective cap
Installation position
Arbitrary, except for keyboard facing up.
Fastening dimension
68x68
Switching functions
0-1
Switching frequency
60/h
Pre-insurance
16A gL/gG
Ambient temperature
-10°C...+40°C
Housing material
PP black
Material collar plug
PA6 red
Protection class
IP54
Conformity
CE