Automatic star-delta starter 11kW 400V/AC-3 16A
with undervoltage release, overload protection, and electronic brake
Item No. 0098.4014
Special Features
- Inrush current limiting when starting asynchronous motors
- Reduction of the starting current to one-third of the value during direct starting
- Optimal, operator-independent ramp-up time for your application
- Drive- and grid-friendly starting
- Various designs available
- Control panel can be placed externally
Automatic star-delta starters are used for asynchronous motors from 4 kW to prevent unacceptably high starting currents during startup. The advantage over manually operated star-delta starters is that these starters feature control logic or can be manually actuated, allowing the ramp-up time to be optimally adjusted to the specific application.
The starting process is implemented with a contactor control, a special time relay (KLIBO Star-Delta Timer), and an integrated overload relay. By adhering to important switching sequences and locking of the control, high operational safety is achieved.
The switching time should be set so that when switching from star to delta, at least 80% of the rated speed is reached. A motor suitable for star-delta starting must have a voltage output of 380V / 660V at a line voltage of 380V or delta 380V. For connection, motors with 6 lead-out winding ends are required.
These star-delta starters are used in machine tools, woodworking machines, compressors, and much more. Furthermore, these starters can also be implemented with our new brake controls.
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0098.4014 | 3 day(s) | 5 |
Technical Features
Series Specifications
Star-delta conversion
Automatic
Network form
3-phase 400V
Housing color
gray
Individual Parameters
Switching power
11kW 400V~/AC-3
Under-voltage release
230V/50Hz
Yes
25 A
Star-delta conversion
Automatically with adjustable ramp-up time via KLIBO Star-Delta brake timer.
Max. rated motor current
24 A
Overload protection
Yes, adjustable
Setting overload protection
Motor nominal current x 0.58 - Please specify the motor nominal current at the end of the ordering process.
Note on motor
The motor must be suitable for a 400V delta connection.
electronic brake
Yes
brake execution
KLIBO phase brake 400V
Maximum braking current.
16 A
Main switch
No
Emergency stop
No
L-0-R switching
No
Network connection
2m H07RN-F 5G2.5 (cable to main switch)
Motor connection
1.5m PUR 7G2.5
Limit switch connection possible
No
Enclosure
K4000
Housing dimensions (LxWxH)
240 x 190 x 128 mm
Mounting dimension
5.3mm through holes 152x223mm and M5 threaded inserts 94x200mm
protection type
IP54
Manufacturer