Automatic star-delta starter 11kW 400V/AC-3 25A for compressors
with overload protection and main switch, pressure switch connection, relief valve connection 230V
Item No. 0098.4016
Setting for the built-in overload protection:
(setting values for overload protection = rated motor current x 0.58)
Rated motor current 6.0-8.3 = setting 3.5-4.8A
Rated motor current 7.8-10.9 = setting 4.5-6.3A
Rated motor current 9.5-12.0 = setting 5.5-7.5A
Rated motor current 12.4-17.2 = Setting 7.2-10.0A
Rated motor current 15.5-21.5A = Setting 9-12.5A
Motor rated current 19.5A-27.6A = setting 11.3-16A(*)
(*) Fitted as standard
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0098.4016 | 3 day(s) | 25 |
Technical Features
Series Specifications
Star-delta conversion
Automatic
Network form
3-phase 400V
Housing color
gray
Individual Parameters
Switching power
11kW 400V~/AC-3
Under-voltage release
230V/50Hz
Yes
25 A
Star-delta conversion
Automatic with adjustable ramp-up time via KLIBO star-delta timer.
Max. rated motor current
24 A
Overload protection
Yes, adjustable
Setting overload protection
Motor rated current x 0.58
Note on motor
Motor must be suitable for 400V delta circuit.
electronic brake
No
Main switch
Yes
Emergency stop
No
L-0-R switching
No
Network connection
2m H07RN-F 5G2.5 with mounted CEE plug 3P+N+E 400V 32A with phase converter.
Motor connection
1.5m PUR 7G2.5
Limit switch connection possible
No
Note
Connection pressure switch and relief valve 230V each via 4mm² spring terminal blocks.
Enclosure
K4000
Housing dimensions (LxWxH)
240 x 190 x 128 mm
Mounting dimension
5.3mm through holes 152x223mm and M5 threaded inserts 94x200mm
protection type
IP54
Manufacturer
Klinger & Born GmbH, In den Schlangenäckern 5, DE - 64395 Brensbach