Automatic starter 3-phase
with CCST control board, selector switch manual-0-auto for suction and fastening tabs; Total load: 16A or 7.5kW, max. output load: 4.0kW
Item No. 0098.3933
Features
- Plug & Play, no installer required
- Comfortable starting of extraction systems
Please note
- To ensure functionality, the extraction system must not have an undervoltage release.
- Each master socket independently activates the two slave sockets.
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0098.3933 | 1 day(s) | 12 |
Technical Features
Series Specifications
Input voltage
400V/50Hz
Total load
16A or 7.5kW
Max. power master
16A
max. output load
4.0kW 400V/AC-3
Please note
The permissible total connection power of the master and slave must not exceed the specified total load.
Max. switching frequency
20/h
Ambient temperature
-10°C...+40°C
Degree of protection
Enclosure IP54, socket IP44
Individual Parameters
Network connection
CEE flange plug 3P+N+E 400V 16A with phase changer
Adjustable switching times
Yes
Mode selector switch
Yes
Number of master outlets
1x CEE socket 3P+N+E 400V/16A, 1x safety socket 2P+E 230V
Number of slave sockets
1x CEE socket 3P+N+E 400V/16A, 1x protective contact socket 2P+E 230V
Contactor for slave
ISKRA K07
switch-on threshold
~0.1 ... 0.6A adjustable
shut-off threshold
~0.1 ... 0.4A
Turn-on delay
~0.5 ... 8s adjustable
Power-off delay
~0.1 ... 12s adjustable
Mounting tabs
Yes
Dimensions
258x125x145 mm
Weight approx.
1.3 kg
Manufacturer
Klinger & Born GmbH, In den Schlangenäckern 5, DE - 64395 Brensbach
Downloads
Dimension drawing Circuit diagram
Downloads for the Series
Operating manual Security informationFunction description
Delay switches are used to turn on and off electric motors or other inductive loads with a time delay. This is an important feature to ensure smooth starting. When electric motors are switched on, high inrush currents occur, which can be approximately six times the rated current. If two motors are turned on simultaneously, the starting currents can reach levels that may cause the upstream fuse to trip. To prevent this, the second drive is turned on with a delay switch. This has the additional advantage that the second drive automatically switches on after about 3 seconds without further operation and automatically switches off after the main drive is turned off. This is a useful feature for extraction systems and much more. Through the Auto-0-Manual switch (optional), the extraction (Slave) can also be activated even when the saw (Master) is not switched on. Each Master socket independently activates the two Slave sockets.