Automatic starter 3-phase with CCST control board
Power connection: 1-phase 230V or 3-phase 400V 16A
Item No. 0098.3939
Connection options:
Master: 2x 3P+N+E, 2x P+N+E (expandable on request)
Slave: 1x 3P+N+E or P+N+E
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0098.3939 | 1 day(s) | 9 |
Technical Features
Series Specifications
Operating voltage
1Ph-230V or 3Ph-400V1Ph-230V o
Network connection
1-phase 230V or 3-phase 400V (with neutral conductor)
Emergency stop switch
32A, 11.5kW AC-23
Max. total load
11.5kW/400V
Master (expandable on request)
2x 3P+N+E
Slave
2x live+neutral+earth
Permissible load current (Master)
16A
Max. output load switched (slave)
7.5kW/400V or 4.0kW/230V
Contactor for slave
Klibo 7.5
input terminals
3x M20 cable gland, 3x M20 blind plug
Connections network, motor and slave
WAGO TOBJOB spring-loaded terminals, 2.5 mm² clamping range for solid wires 0.25...4 mm² clamping range for fine wires 0.25...4 mm² strip length 10...12 mm
Threshold
Execution with CCST board ~0.1 ... 0.6A adjustable
Cut-off threshold
~0.1 ... 0.4A
turn-on delay
~0.5 ... 8s adjustable
Turn-off delay
~0.1 ... 12s adjustable
Pre-insurance (by construction site)
16A gL/gG
Max. switching frequency
20/h
ambient temperature
-10°C ... +40°C
Housing
Technopolymer, gray. IK07
Protection class
IP56
Individual Parameters
Network connection
1Ph-230V or 3Ph-400V 16A (with neutral conductor)
Adjustable switching times
Yes
Mode selector switch
Yes
Number of master outlets
without
Number of slave sockets
without
Contactor for slave
Klibo 7.5
switch-on threshold
Adjustable from ~0.1 ... 0.6A
shut-off threshold
~0.1 ... 0.4A
Turn-on delay
adjustable from ~0.5 to 8s
Power-off delay
~0.1 ... 12s adjustable
Mounting tabs
No
Dimensions
240 x 190 x 162 mm
Weight approx.
2.6 kg
Manufacturer
Klinger & Born GmbH, In den Schlangenäckern 5, DE - 64395 Brensbach
Downloads
Dimension drawing Schematic diagram
Downloads for the Series
Operating manual Security informationFunctional description
Delay switches are used to switch on and off, for example, electric motors or other inductive loads with a time delay. This is an important feature to ensure smooth starting. When switching on electric motors, high inrush currents occur, which can be approximately six times the nominal current. If two motors are switched on simultaneously, the starting currents may be in a range that can trigger the upstream fuse. To prevent this, the second drive is switched on with a delay using a delay switch. This has the additional advantage that the second drive switches on automatically after about 3 seconds without further operation and switches off automatically after the main drive is turned off. This is a useful feature for extraction systems and much more. The Auto-0-Hand switch (optional) allows the extraction (Slave) to be operated even when the saw (Master) is not switched on. Each master socket independently activates the two slave sockets.