KLIBO start brake 400V 50/60Hz, 25A
- Replaced by 8503.4492 -
Item No. 8503.4491
Features
- Continuously adjustable braking time
- Continuously adjustable braking current
- Optimized controller control allows restarting during the braking phase
- Relay outputs 5A
- Switchable braking currents via control of power contactors
- Controller-controlled with watchdog
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
8503.4491 | 0 day(s) | 0 |
Technical Features
Series Specifications
Nominal frequency
50-60Hz
Voltage range
85-110%
Rated power
2VA
ambient temperature
-20°C ... +50°C
Control input K1
Optional, same potential as input L3.
braking time
3 sec ... 20 sec
Max. braking current
0 - 20A
Power semiconductor
Thyristor = 30A/1200V Diode = 40A/1200V
braking frequency
10% ED at 10 sec. braking time (36/h)
Restart delay
Approximately 400ms
Operation mode
Controller-controlled with watchdog
Housing 10-pole.
Din rail enclosure
fastening
On DIN rail (EN60715)
Dimensions of the housing
45.5 x 74 x 85mm (LxWxH)
Max. connection cross-section
2.5mm²
Individual Parameters
Manufacturer
Klinger & Born GmbH, In den Schlangenäckern 5, DE - 64395 Brensbach
Downloads
Downloads for the Series
Circuit diagram 3Ph-400V with control voltage 24VCircuit diagram 3-phase 400V with control voltage
Schematic diagram 3Ph-400V with control voltage 23
Wiring diagram 3-phase 400V with control voltage 4
Wiring diagram 3-phase 400V with control voltage 4
Connection designations
Function description
The KLIBO start brake system is designed for the direct starting and braking of cage rotor motors and single-phase motors with starting capacitors. The integrated power electronics (inverter) generate a direct current that creates a stationary magnetic field in the motor winding and brakes the rotor. The magnetic field strength and thus the braking force is determined by the magnitude of the adjustable direct current. The module allows for stepless adjustment of the braking time and the braking current. A controller manages and monitors the operating condition, ensuring safe re-engagement even during the braking process. The start relay and the brake relay are safely switched via two independent output relays. The brake relay switches the braking current to the motor winding. To achieve the maximum braking torque, the braking current can be switched over 2 or even 3 windings depending on the wiring and motor type.
Motor heating during braking operation:
The motor heating during braking due to direct current supply corresponds to the heating during motor start-up. If motors are frequently started and braked with high currents, the motor temperature should additionally be monitored by a thermistor (temperature sensor).