Star-delta starter 7.5kW 400V/AC-3 16.0A
manual, with undervoltage release, overload protection, and main switch
Item No. 0098.3501
Setting for the built-in overload protection:
(Setting values for overload protection = Motor nominal current x 0.58)
Motor nominal current 6.0-8.3A = Setting 3.5-4.8A
Motor nominal current 7.8-10.9A = Setting 4.5-6.3A
Motor nominal current 9.5-12.0A = Setting 5.5-7.5A
Motor nominal current 12.4-17.2A = Setting 7.2-10.0A (*)
(*) Installed as standard
Versions
| Item No. | Delivery Time | Stock | Quantities / Prices |
|---|---|---|---|
| 0098.3501 | 3 day(s) | > 5 | 181,23 € Net |
Technical Features
Series Specifications
Star-delta transformation
Manually operated
Network shape
3-phase 400V
Case color
gray
Individual Parameters
Switching power
7.5kW 400V~/AC-3
Under-voltage release Uc
400V/50Hz
Yes
16 A
Max. rated motor current
16 A
Overload protection
Yes, adjustable
Setting overload protection
Motor rated current x 0.58 - Please specify the motor rated current at the end of the ordering process.
Note on motor
Motor must be suitable for 400V delta connection.
electronic brake
No
Main switch
Yes
Emergency stop
No
L-0-R switching
No
Network connection
CEE plug 400V 16A 3P+N+E with phase inverter
Motor connection
1m S07RN-F 7G 1.5 with M6 cable lugs
Limit switch connection possible
No
Housing
K3500
Case dimensions (LxWxH)
200 x 140 x 112 mm
Mounting dimensions
4 threaded bushings for screws M5, 118x174mm and 5.3 through holes 102x183mm
Degree of protection
IP54
Manufacturer