Starter K3000 3Ph-400V
with undervoltage release
Item No. 0099.3006
Undervoltage release in accordance with IEC204-1, EN60204, VDE0113, section 7.5, for protection against automatic restart after voltage dip and voltage recovery
Versions
| Item No. | Delivery Time | Stock | Quantities / Prices |
|---|---|---|---|
| 0099.3006 | 1 day(s) | > 5 | 92,74 € Net |
Technical Features
Series Specifications
Startup
Direct startup
Rated operating voltage Ue
400V/50Hz
Rated operating current Ie
16A
Connection
3-phase 400V
Keypad
with protective cap
Installation position
Arbitrary
Pre-insurance
16A gL/gG
Ambient temperature
-10°C...+40°C
Impact resistance
IK08
Conformity
CE
Individual Parameters
Switching power
4.0kW 400V~/AC-3
contactor
KB-04
Network input
3m power cord H07RN-F 5G1.5 with mounted CEE plug 16A 400V with phase inverter.
Motor connection
terminal block connectors
additional line input
No
Type of operation
Push buttons on/off
Actuation
mechanical on/off
Switching functions
0-1
switching frequency
60/h
Undervoltage release Uc
230V 50/60Hz
Control circuit fuse
No
electronic brake
No
Circuit for mechanical brake
No
Overload protection
No
Emergency stop
No
Rotary field detection
No
Pole switch
No
Limit switch connection possible
No
Mounting dimension
68x68mm
Mounting tabs
No
Weight approx.
1,464 kg
Manufacturer
Klinger & Born GmbH, In den Schlangenäckern 5, DE - 64395 Brensbach
Downloads
Dimension drawing
Circuit diagrams
Safety information