Starter K400 3Ph-400V
with undervoltage release and overload protection
Item No. 0098.8810
Undervoltage release in accordance with IEC204-1, EN60204, VDE0113, section 7.5, for protection against automatic restart after voltage dip and voltage recovery
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0098.8810 | 3 day(s) | 43 | 72,73 € Net |
Technical Features
Series Specifications
Start-up
Direct start
Rated operating voltage Ue
400V/50Hz
rated switching capacity
4.0kW 400V~
Rated operational current Ie
9.0A
Connection
3-phase 400V
Contactor
KB-04
Network input
Network cable
Actuation type
Push buttons on/off
Button panel
with protective cap
Installation position
Arbitrary, except for keyboard upwards.
Mounting dimension
68x68mm
Switching functions
0-1
Switching frequency
60/h
pre-insurance
16A gL/gG
Ambient temperature
-10°C...+40°C
Housing material
ABS black or yellow
Protection class
IP54
Conformity
CE
Individual Parameters
network input
3 m H07RN-F 5G 1.5 with CEE plug 3P+N+E 400V 16A
Motor connection
0.8m H07RN-F 4G 1.5
Under-voltage release Uc
230V/50Hz
electronic brake
No
Overload protection
Yes, 3-pole.
Setting overload protection
1...9A, fixed setting - Please specify motor rated current at the end of the ordering process.
Actuation
mechanical on/off
Switching frequency
60 per hour
Weight
1.25 kg
Manufacturer
Klinger & Born GmbH, In den Schlangenäckern 5, DE - 64395 Brensbach
Downloads
Dimension drawing
Schematic diagram