Starters 3Ph-400V with Dahlander switching up to 5.5 kW - Optional up to 7.5 kW
with undervoltage release, overload protection, main switch, electronic brake, emergency stop, control voltage 230V
Item No. 0098.4086
Features
- Overload protection, with overload relay or thermistor relay
- additional connection option for feed
- automatic star-delta start
- connections with spring-loaded terminals
- for external control panel
Versions
Item No. | Delivery Time | Stock | Quantities / Prices |
---|---|---|---|
0098.4086 | 3 day(s) | 6 |
Technical Features
Series Specifications
Under-voltage release
Yes
Overload protection
Yes, adjustable
Emergency stop
Optional
electrical brake
Optional
Main switch
Optional
Individual Parameters
Start-up
Direct starter - Dahlander
Switching power max.
7.5kW 400V~/AC-3
Yes
16.0 A
Control voltage
Uc: 230V/50Hz
electronic brake
Yes
brake execution
Phase brake 400V
Max. braking current
16.0 A
Overload protection
Yes
Setting overload protection
7.5-11A adjustable - Please specify the motor nominal current at the end of the ordering process.
Main switch
Yes
Main switch design
48x48mm, lockable
start-stop keyboard
green-red with protective cap
Emergency stop
Yes
Pole switch
Δ / YY
Network connection
3m power cable H07RN-F 5G1.5 with attached CEE plug 3P+N+E 400V/16A with phase inverter
Motor connection
2m motor cable H07RN-F 7G1.5
Housing
K4000
Housing dimensions (LxWxH)
240 x 190 x 128 mm
Mounting
5.3mm through holes 152x223mm and M5 threaded inserts 94x200mm
degree of protection
IP54 (IP65 on request)
Weight
3.749 kg
Manufacturer