Overload protection Klibo Mxx,xA

The optimal protection for your engine.

Overload protection Mxx,xA
Description

Features


  • Cost-effective
  • Compact design
  • Safe and simple operation
  • Very good price-performance ratio
  • Individual customization according to specific customer requests possible
  • Short delivery time due to in-house production
  • Motor protection according to IEC204-1, EN60204-1, DIN VDE0113 Part 1 / IEC947-4-1, EN60947-4-1, DIN VDE0660 Part 102


Release characteristic see "More Images"

Series Specifications

Field

0.6...16.0 A

Adjustment

Factory setting (according to nominal current specification)

Explanations

1-pole, 2-pole, 3-pole

Mode of operation

Thermal bimetal, activation via microswitch.

Ue

400 V

UI

400 V

switching voltage

Max. 400V~

Switching power of the relay

2(0.5)A 250V~

Restoration

Automatic

Trigger class

10 A

B10 (B10d)

1,000,000 (1,500,000)

Design form

Insert

Housing material

PA6.6 V-0

Recommended overcurrent protection (at 400V) for rated current 0.16 - 0.60A

4 A

Recommended pre-fuse (at 400V) for rated current 0.60 - 1.00A

6 A

Recommended pre-fuse (at 400V) for rated current 1.00 - 1.60A

10 A

Recommended pre-fuse (at 400V) for rated current 1.60 - 16.0A

16 A

Trip characteristic Ie x 1.05

Trigger time t>2h

Release characteristic Ie x 1.20

Trigger time t<2h

Trigger characteristic Ie x 1.50

Trigger time t<2min

Additional Views and Drawings
Trigger characteristics
Trigger characteristics